Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Language
Year range
1.
Psico (Porto Alegre) ; 50(2): e30033, 2019.
Article in English | LILACS | ID: biblio-1008333

ABSTRACT

The objective of this study was to investigate whether there is a relationship between pupil diameter and facial attractiveness. Participated in the study 60 young adults (30 men and 30 women) between 18 and 26 years of age (M=20.65, SD=2.20). Ten different unfamiliar neutral faces (five men and five women) were used as stimuli. The pupil diameter of each face was manipulated with pupil diameters of 2, 3, 4, 5 and 6mm (10 faces x5 pupil diameters=50 stimuli). A two-step study was carried out with the same sample and the same sets of faces, seeking to understand the difference of responses between subjects of both sexes. In phase I, result indicated a significant difference in relation to the pupil diameter factor for both the men (ꭓ²=21.93, p<.05) and the women (ꭓ²=44.73, p<.05). In phase II, the results indicated significant differences in relation to the pupil size [F(1, 234)=19.06, p<0.05]. The post-hoc Tukey HSD test showed that both the men and the women differently judged the faces with a pupil diameter of 2mm in relation to the faces with pupil diameters of 3, 4, 5 and 6mm (p<.05). Also, a significant difference between the diameter of 5mm in relation to the diameter of 3mm (p<.05). In general, the results indicate that the pupil diameter is a structural component of the human face that plays an important role in the process of judging facial attractiveness.


O objetivo deste estudo foi investigar a relação entre o diâmetro da pupila e a atratividade facial. Participaram da pesquisa 60 jovens com idade entre 18 e 26 anos. Foram utilizadas dez faces de adultos jovens, manipulou-se o diâmetro de cada pupila com variações de 2, 3, 4, 5 e 6mm. Realizou-se um estudo em duas etapas: na fase I, o resultado indicou diferença significativa para o fator de diâmetro pupilar tanto para homens quanto para mulheres (p<0,05). Na fase II, os resultados indicaram diferenças significativas em relação ao tamanho da pupila (p<0,05). O teste post-hoc Tukey mostrou que tanto os homens quanto as mulheres avaliaram diferentemente as faces com diâmetro pupilar de 2mm (p<0,05). Em geral, os resultados indicam que o diâmetro da pupila é um componente da face humana que desempenha um importante função no processo de julgamento da atratividade facial.


El objetivo de este estudio fue investigar si existe una relación entre el diámetro pupilar y el atractivo facial. Participaron en la estudio 60 adultos jóvenes (30 hombres y 30 mujeres) entre 18 y 26 años de edad (M=20.65, DE=2.20). Se utilizaron como estímulos diez rostros neutrales desconocidos diferentes (cinco hombres y cinco mujeres). El diámetro de la pupila de cada cara se manipuló con diámetros de pupila de 2, 3, 4, 5 y 6mm (10 caras x5 diámetros de pupila=50 estímulos). Se realizó un estudio en dos etapas con la misma muestra y los mismos conjuntos de caras buscando entender la diferencia de respuestas entre sujetos de ambos sexos. En la fase I, el resultado indicó una diferencia significativa en relación al factor de diámetro de la pupila tanto para los hombres (ꭓ²=21.93, p <0.05) como para las mujeres (ꭓ²=44.73, p<0.05). En la fase II, los resultados indicaron diferencias significativas en relación al tamaño de la pupila [F(1, 234)=19,06, p<0,05]. La prueba post-hoc de Tukey HSD mostró que tanto los hombres como las mujeres evaluaron de manera diferente las caras con un diámetro pupilar de 2mm con respecto a las caras con diámetros pupilares de 3, 4, 5 y 6mm (p<0,05). Se observó una diferencia significativa entre el diámetro de 5mm en relación al diámetro de 3mm (p<0,05). En general, los resultados indican que el diámetro de la pupila es un componente estructural de la cara humana que desempeña una importante función en el proceso de juicio del atractivo facial.


Subject(s)
Pupil , Interpersonal Relations , Eye , Face
2.
Arq. bras. med. vet. zootec ; 68(3): 641-650, tab, graf
Article in English | LILACS, VETINDEX | ID: lil-785710

ABSTRACT

The aim of this study was to evaluate changes in intraocular pressure (IOP), pupil size (PS), blood pressure (BP), heart rate (HR), and ECG variables (Pms wave PmV, PR interval, QRS complex, RMV wave and QT intervals) over time during the instillation of 0.5% timolol, 0.5% levobunolol and 0.5% apraclonidine in clinically normal dogs. Ten adult beagles were used. Baseline values were measured at 8a.m., 2p.m. and 8p.m., for three consecutive days. A waiting period of 10 days between the administrations of each drug was established. For 15 consecutive days, the drug being tested was instilled in one eye of each dog twice a day (7a.m. and 7p.m.). The parameters were evaluated at the aforementioned times on days 3, 6, 9, 12 and 15. Data were statistically compared using the Bonferroni test and one-way repeated measures analysis of variance (P<0.05). The Pearson test was used to evaluate any correlation between QT interval, HR and BP. The tested drugs did not find a decrease in IOP. A significant decreased in PS was observed in almost all dogs following levobunolol administration, relative to the control eye. A significant decrease in HR was observed on day 3 following levobunolol treatment, while apraclonidine induced an increase on day 15. Blood pressure was reduced in all measurement time points following apraclonidine treatment. A negative correlation between QT interval and HR was only observed in dogs treated with timolol. In conclusion, levobunolol was the only drug that induced significant alterations in PS. Apraclonidine was the only drug that induced systemic hypotension. Timolol was the only drug to that induced a negative correlation between QT and HR.(AU)


O objetivo deste estudo foi avaliar as mudanças na pressão intraocular (PIO), no diâmetro pupilar (DP), na pressão sanguínea (PS), na frequência cardíaca (FC) e nas variáveis eletrocardiográficas (onda Pms, PmV, intervalo PR, complexo QRS, onda RmV e intervalo QT), ao longo do tempo da instilação do timolol 0,5%, do levobunolol 0,5% e da apraclonidina 0,5% em cães clinicamente normais. Dez Beagles adultos compuseram o estudo. Valores basais foram mensurados às oito,, 14 e 20 horas, durante três dias consecutivos. Foi instituído um período de espera de 10 dias entre a administração de cada fármaco. Durante 15 dias consecutivos, um olho de cada animal recebeu uma gota de cada um deles, a intervalos de 12 horas (às sete e às 19 horas). Os parâmetros foram avaliados nos momentos acima referidos, nos dias três, seis, nove, 12 e 15. Os dados foram comparados estatisticamente empregando-se o teste de Bonferroni após análise de variância para medidas repetidas (P<0,05). Teste de Pearson foi utilizado para correlação entre o intervalo QT com a FC e a PS. Não se encontrou diminuição da PIO. Observou-se redução significativa do DP na quase totalidade dos animais que receberam levobunol, relativamente ao olho controle. Diminuição significativa da FC foi vista ao terceiro dia após a administração do levobunolol, enquanto apraclonidina induziu aumento no 15º dia. A pressão arterial foi reduzida em todos os momentos com a apraclonidina. Observou-se correlação negativa entre o intervalo QT e a FC apenas nos indivíduos tratados com o timolol. Em conclusão, levobunolol foi o único fármaco que induziu alterações significativas no DP. A apraclonidina foi o único fármaco que induziu hipotensão sistêmica significativa. O timolol foi o único a ensejar correlação negativa entre o intervalo QT e a FC.(AU)


Subject(s)
Animals , Dogs , Blood Pressure , Heart Rate , Intraocular Pressure , Levobunolol/adverse effects , Levobunolol/analysis , Timolol/adverse effects , Timolol/analysis , Analysis of Variance , Instillation, Drug , Pupil
3.
Arq. bras. med. vet. zootec ; 60(5): 1045-1052, out. 2008. ilus
Article in English | LILACS | ID: lil-500068

ABSTRACT

The effects of topical levobunolol with the fixed combination of 2 percent dorzolamide-0.5 percent timolol and the association of 2 percent dorzolamide with 0.5 percent levobunolol on intraocular pressure (IOP), pupil size (PS), heart rate (HR), and conjunctival hyperemia in eighteen halthy cats were investigated and compared. IOP, PS, HR, and conjuntival hyperemia were daily recorded at three times (9a.m., 2p.m., and 6p.m.). Three groups were formed (n=6), and one eye of each animal was randomly selected and treated with topical levobunolol (L), or commercial combination of dorzolamide-timolol (DT), or the association of dorzolamide with levobunolol (DL). The first day (0) consisted of recording of baseline values. On the next four consecutive days, drugs were instilled at 8a.m. and 8p.m. and measurements were taken at the same times fore cited. Comparing with the baseline values, all evaluated parameters significantly decreased (P<0.001). Conjuntival hyperemia was not seen. Levobunolol significantly declined IOP, PS, and HR in normal cats, and showed a stronger effect in lowering HR, when compared to dorzolamide-timolol effect. No synergistic effect in IOP declining was noted when levobunolol dorzolamide was added to levobunolol.


Estudaram-se e compararam-se os efeitos do levobunolol, da combinação fixa de dorzolamida 2 por cento-timolol 0,5 por cento e da associação de dorzolamida 2 por cento com levobunolol 0,5 por cento sobre a pressão intra-ocular (PIO), o diâmetro pupilar (DP), a freqüência cardíaca (FC) e a hiperemia conjuntival em 18 gatos saudáveis. PIO, DP, FC e hiperemia conjuntival foram aferidos diariamente, em três horários distintos (9h, 14h e 18h). Três grupos foram formados (n=6) e um olho de cada animal recebeu, aleatoriamente, uma gota de levobunolol (L), ou a combinação comercial à base de dorzolamida-timolol (DT), ou a associação de dorzolamida com levobunolol (DL). Parâmetros basais foram aferidos no primeiro dia (dia 0). Nos quatro dias consecutivos, os fármacos foram instilados às 8h e 20h e os parâmetros aferidos nos mesmos horários. Todos os parâmetros decresceram significativamente em relação aos valores basais (P<0,001) e não se observou hiperemia conjuntival. O levobunolol reduziu significativamente a PIO, o DP e a FC e o foi o fármaco que mais reduziu a FC. Não se observou efeito sinérgico na redução da PIO quando a dorzolamida foi adicionada ao levobulol.


Subject(s)
Animals , Cats , Heart Rate , Intraocular Pressure , Levobunolol/adverse effects , Pupil/physiology
SELECTION OF CITATIONS
SEARCH DETAIL